Beacon project:

HOUSE IN GÉNOVA, MALLORCA

E-07015 Génova (Palma, Balearic Islands), Other associated region, Spain
Contact Vogt, Anne

See www.passivehouse-database.org for more information

Paloma Hernaiz and Jaime Oliver, OHLAB
Paloma Hernaiz and Jaime Oliver, OHLAB
Paloma Hernaiz and Jaime Oliver, OHLAB
Paloma Hernaiz and Jaime Oliver, OHLAB
Paloma Hernaiz and Jaime Oliver, OHLAB
Paloma Hernaiz and Jaime Oliver, OHLAB
3D model DesignPH, VAND Arquitectura
3D model DesignPH, VAND Arquitectura
Paloma Hernaiz and Jaime Oliver, OHLAB

 

Website

www.ohlab.net


Email


Timeline

Beacon Timeline 2012 2013 2014 2015 2016 2017 2018 2019 2020
May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Pre Design Building specification                                                                                                                                                                                                                
Planning                                                                                                                                                                                                                
Design Preliminary design                                                                                                                                                                                                                
Working design                                                                                                                                                                                                                
Detailed Design Detailed design/elaboration                                                                                                                                                                                                                
Construction Construction                                                                                                                                                                                                                
Commissioning/handover                                                                                                                                                                                                                
Occupancy & Operation Post ccupancy commissioning                                                                                                                                                                                                                
Ordinary operation                                                                                                                                                                                                                
Monitoring Energy performance measurements                                                                                                                                                                                                                
Quality Assurance Info session                                                                                                                                                                                                                
Airtightness test                                                                                                                                                                                                                
Thermographic imaging                                                                                                                                                                                                                
On-site training of workers                                                                                                                                                                                                                
Building vertification                                                                                                                                                                                                                
Renewable technology certification                                                                                                                                                                                                                
User comfort survey                                                                                                                                                                                                                

General description

Detached single family house designed following the Passive House principles in a traditional concrete and brick construction with exterior ETICS insulation. The access of the house is from the closed west facade, with a small hall which leads to the two volumes in the north with the bedrooms, to the main volume with the living room in the ground floor and an office in the first floor, and the volume of the kitchen facing the south. Although the buildings geometry follows the architectural concept and is not compact which is a disadvantage in winter, this lower compactness helps in summer to avoid overheating. The design does also take into account renewable energies by using solar panels. On the other hand it counts with a system of rain water use with storage below the building which makes the owners totally independent from public water supply. ARCHITECT: Paloma Hernaiz and Jaime Oliver, OHLAB, Madrid // QUANTITY SURVEYOR: Jorge Ramón Monegal // STRUCTURAL ENGINEER: Jesús Alonso // COLLABORATION ARCHITECT: Rebeca Lavín, Walter Brandt, Sergio Rivero de Cáceres // PHPP CALCULATIONS AND PH ASSESSMENT: Anne Vogt, VAND arquitectura, Madrid.


Project type

New build


Project scale

individual building


Ownership type

privately owned


Building type and size

detached single family house


Treated Floor Area according to PHPP

136,30m²


Gross construction costs

1,500€/m2 (EUR/m² of Treated Floor Area)


Gross building strucutre + technical service costs

2,200€/m2 (EUR/m² of Treated Floor Area)


Passive house database

Find this project at www.passivehouse-database.org


Files

AXO.A4.pdf - OHLAB, Oliver Hernaiz Architecture Lab




Intelligent Energy Europe
Partner
PassREg
Passive House Regions with Renewable Energies